The paper gives results of pilot-plant tests of electrostatic fabric filtration (ESFF) at Harrington Station, near Amarillo, Texas. In early 1983, the pilot baghouse at Harrington Station was modified to conduct a testing program for ESFF. The tests conducted there successfully demonstrated the ESFF concept on a commercial scale and confirmed the favorable effect of reduced-filtration pressure drop previously observed in both laboratory and small scale tests. The unique woven-in electrode concept employed was successfully demonstrated from both bag construction and operational standpoints.
Research Organization:
Southwestern Public Service Co., Amarillo, TX (USA)
OSTI ID:
6662376
Report Number(s):
PB-87-147187/XAB
Country of Publication:
United States
Language:
English