Extended Kalman filter sensor failure detection method for pressurizer monitoring

Conference · · Transactions of the American Nuclear Society; (United States)
OSTI ID:6661097

This work presents the development of the sensor failure detection and isolation system (FDIS) methodology, which is suitable for implementation in nuclear plant control systems. The methodology is based on the extended Kalman filter applied to a pressurized water reactor pressurizer. The utilization of the Kalman filter follows the standard procedure: First, an estimate of the state variables and the corresponding covariances are obtained; then, based on the state equations, the estimated state variables are propagated until the next measurements for the new estimate.