Streaming of 14-MeV neutrons through an iron duct: comparison of measured neutron and gamma-ray energy spectra with results calculated using the Monte Carlo code MCNP
Neutron and gamma-ray energy spectra resulting from the streaming of 14 MeV neutrons through a 0.30-m-diameter duct (length-to-diameter ratio = 2.83) have been calculated using the Monte Carlo code MCNP. The calculated spectra are compared with measured data and data calculated previously using a combination of discrete ordinates and Monte Carlo methods. Comparisons are made at twelve detector locations on and off the duct axis for neutrons with energies above 850 keV and for gamma rays with energies above 750 keV. The neutron spectra calculated using MCNP agree with the measured data within approx. 5 to approx. 50%, depending on detector location and neutron energy. Agreement with the measured gamma-ray spectra is also within approx. 5 to approx. 50%. The spectra obtained with MCNP are also in favorable agreement with the previously calculated data and were obtained with less calculational effort.
- Research Organization:
- Oak Ridge National Lab., TN (USA)
- DOE Contract Number:
- W-7405-ENG-26
- OSTI ID:
- 6653213
- Report Number(s):
- ORNL/TM-8504; ON: DE83003349
- Country of Publication:
- United States
- Language:
- English
Similar Records
Streaming of 14-MeV neutrons through an iron duct--comparison of measured neutron and gamma-ray energy spectra with results calculated using the Monte Carlo MCNP code
Monte Carlo and discrete ordinates calculations of 14-MeV neutrons streaming through a stainless steel duct: Comparison with experiment I
Monte Carlo and discrete ordinates calculations of 14-MeV neutrons streaming through a stainless steel duct: comparison with Experiment I
Journal Article
·
Fri Jul 01 00:00:00 EDT 1983
· Nucl. Sci. Eng.; (United States)
·
OSTI ID:5265534
Monte Carlo and discrete ordinates calculations of 14-MeV neutrons streaming through a stainless steel duct: Comparison with experiment I
Journal Article
·
Mon Mar 31 23:00:00 EST 1986
· Nucl. Sci. Eng.; (United States)
·
OSTI ID:5794857
Monte Carlo and discrete ordinates calculations of 14-MeV neutrons streaming through a stainless steel duct: comparison with Experiment I
Technical Report
·
Thu Feb 28 23:00:00 EST 1985
·
OSTI ID:5959114
Related Subjects
70 PLASMA PHYSICS AND FUSION TECHNOLOGY
700201* -- Fusion Power Plant Technology-- Blanket Engineering
DISCRETE ORDINATE METHOD
DUCTS
ELEMENTS
ENERGY SPECTRA
GAMMA TRANSPORT THEORY
IRON
METALS
MONTE CARLO METHOD
NEUTRAL-PARTICLE TRANSPORT
NEUTRON TRANSPORT
RADIATION STREAMING
RADIATION TRANSPORT
SPECTRA
THERMONUCLEAR REACTORS
TRANSITION ELEMENTS
TRANSPORT THEORY
700201* -- Fusion Power Plant Technology-- Blanket Engineering
DISCRETE ORDINATE METHOD
DUCTS
ELEMENTS
ENERGY SPECTRA
GAMMA TRANSPORT THEORY
IRON
METALS
MONTE CARLO METHOD
NEUTRAL-PARTICLE TRANSPORT
NEUTRON TRANSPORT
RADIATION STREAMING
RADIATION TRANSPORT
SPECTRA
THERMONUCLEAR REACTORS
TRANSITION ELEMENTS
TRANSPORT THEORY