Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Visualization of a prosthetic vascular graft due to platelet contamination during /sup 111/Indium-labeled leukocyte scintigraphy

Journal Article · · J. Nucl. Med. Technol.; (United States)
OSTI ID:6651167

A prosthetic axillo-femoral bypass graft was visualized during /sup 111/In-labeled leukocyte scintigraphy in a patient referred for possible abdominal abscess. The presence of significant cardiac blood-pool activity raised the possibility that this uptake was due to deposition of contaminating labeled platelets rather than labeled leukocytes. An analysis of a small sample of the patient's blood confirmed that the circulating activity was due to labeled platelets. Increased activity along prosthetic vascular grafts in patients undergoing /sup 111/In-labeled leukocyte scintigraphy may be due to adherent platelet, and not indicative of infection.

Research Organization:
Tufts-New England Medical Center, Boston, MA (USA)
OSTI ID:
6651167
Journal Information:
J. Nucl. Med. Technol.; (United States), Journal Name: J. Nucl. Med. Technol.; (United States) Vol. 16:3; ISSN JNMTB
Country of Publication:
United States
Language:
English