Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Failure of Incoloy 800H superheater tubes in Mountain Fuel Resources gasifier

Journal Article · · Mater. Compon. Fossil Energy Appl.; (United States)
OSTI ID:6649581
Details are given of the early failure of superheater tubes on Mountain Fuel Resources' entrained-flow gasification PDU. Examination showed the failure to have occurred from the outside by intergranular stress corrosion cracking. Steps that can be taken to prevent this re-occurring are considered.
OSTI ID:
6649581
Journal Information:
Mater. Compon. Fossil Energy Appl.; (United States), Journal Name: Mater. Compon. Fossil Energy Appl.; (United States) Vol. 49; ISSN MCFAD
Country of Publication:
United States
Language:
English