Neutron detection and multiplicity counting using a boron-loaded plastic scintillator/bismuth germanate phoswich detector array
Neutron detection and multiplicity counting has been investigated using a boron-loaded plastic scintillator/bismuth germanate phoswich detector array. Boron-loaded plastic combines neutron moderation (H) and detection ({sup 10}B) at the molecular level, thereby physically coupling increasing detection efficiency and decreasing die-away time with detector volume. Both of these characteristics address a fundamental limitation of thermal-neutron multiplicity counters, where {sup 3}He proportional counters are embedded in a polyethylene matrix. Separation of the phoswich response into its plastic scintillator and bismuth germanate components was accomplished on a pulse-by-pulse basis using custom integrator and timing circuits. In addition, a custom time-tag module was used to provide a time for each detector event. Analysis of the combined energy and time event stream was performed by calibrating each detector`s response and filtering based on the presence of a simultaneous energy deposition corresponding to the {sup 10}B(n,alpha) reaction products in the plastic scintillator (93 keV{sub ee}) and the accompanying neutron-capture gamma ray in the bismuth germanate (478 keV). Time-correlation analysis was subsequently performed on the filtered event stream to obtain shift-register-type singles and doubles count rates. Proof-of-principle measurements were conducted with a variety of gamma-ray and neutron sources including {sup 137}Cs, {sup 54}Mn, AmLi, and {sup 252}Cf. Results of this study indicate that a neutron-capture probability of {approximately}10% and a die-away time of {approximately}10 {micro}s are possible with a 4-detector array with a detector volume of 1600 cm{sup 3}. Simulations were performed that indicate neutron-capture probabilities on the order of 50% and die-away times of less than 4 {micro}s are realistically achievable. While further study will be required for practical application of such a detection system, the results obtained in this investigation are encouraging and may lead to a new class of high-efficiency, short die-away time neutron multiplicity counters capable of extending current nondestructive assay methods for special nuclear materials.
- Research Organization:
- Los Alamos National Lab., NM (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 663186
- Report Number(s):
- LA--13315-T; ON: DE98006019
- Country of Publication:
- United States
- Language:
- English
Similar Records
Neutron detection and applications using a BC454/BGO array
The feasibility of using boron-loaded plastic fibers for neutron detection
Development of a Phoswich Neutron Detector with Energy Spectroscopy Capability
Conference
·
Mon Nov 30 23:00:00 EST 1998
·
OSTI ID:296758
The feasibility of using boron-loaded plastic fibers for neutron detection
Conference
·
Mon Nov 30 23:00:00 EST 1998
·
OSTI ID:296759
Development of a Phoswich Neutron Detector with Energy Spectroscopy Capability
Journal Article
·
Wed Jun 15 00:00:00 EDT 2016
· Transactions of the American Nuclear Society
·
OSTI ID:22992049