Test procedures and instructions for Hanford tank waste supernatant cesium removal

Technical Report ·
DOI:https://doi.org/10.2172/662046· OSTI ID:662046

This document provides specific test procedures and instructions to implement the test plan for the preparation and conduct of a cesium removal test using Hanford Double-Shell Slurry Feed supernatant liquor from tank 251-AW-101 in a bench-scale column.Cesium sorbents to be tested include resorcinol-formaldehyde resin and crystalline silicotitanate. The test plan for which this provides instructions is WHC-SD-RE-TP-022, Hanford Tank Waste Supernatant Cesium Removal Test Plan.

Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
662046
Report Number(s):
WHC-SD-RE-TPI--001; ON: DE98053080; BR: EW4010000
Country of Publication:
United States
Language:
English