Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Foreign technology assessment: Environmental evaluation of a radiation-hard oscillator/divider

Technical Report ·
OSTI ID:6620427

Salford Electrical Instruments, Ltd., and the General Electric Company's Hirst Research Centre, under contract to the United Kingdom's (UK) Ministry of Defence, developed a radiation-hard, leadless chip-carrier-packaged oscillator/divider. Two preproduction clocks brought to Sandia National Laboratories (SNL) by a potential SNL customer underwent mechanical and thermal environmental evaluation. Because of the subsequent failure of one device and the deteriorating condition of another device, the devices were not subjected to radiation tests. This report describes the specifics of the environmental evaluation performed on these two clocks and the postmortem analysis of one unit, which ultimately failed. Clock startup time versus temperature studies were also performed and compared to an SNL-designed clock having the same fundamental frequency.

Research Organization:
Sandia National Labs., Albuquerque, NM (United States)
Sponsoring Organization:
DOE; USDOE, Washington, DC (United States)
DOE Contract Number:
AC04-76DP00789
OSTI ID:
6620427
Report Number(s):
SAND-92-2473; ON: DE93011481
Country of Publication:
United States
Language:
English