skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Decant pump assembly and controls qualification testing - test report

Technical Report ·
DOI:https://doi.org/10.2172/662008· OSTI ID:662008

This report summarizes the results of the qualification testing of the supernate decant pump and controls system to be used for in-tank sludge washing in aging waste tank AZ-101. The test was successful and all components are qualified for installation and use in the tank.

Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
662008
Report Number(s):
WHC-SD-ER3297-TRP-001; ON: DE98053058; BR: EW3130010; TRN: 96000325
Resource Relation:
Other Information: PBD: 2 May 1996
Country of Publication:
United States
Language:
English

Similar Records

SAFETY ANALYSIS FOR TANK 241-AZ-101 MIXER PUMP PROCESS TEST
Technical Report · Mon Jun 09 00:00:00 EDT 1997 · OSTI ID:662008

Laboratory testing in-tank sludge washing, summary letter report
Technical Report · Thu Sep 01 00:00:00 EDT 1994 · OSTI ID:662008

Results of the Tank 40H Sludge Batch 2 Final Wash (Post-Decant) Sample HTF-E-133
Technical Report · Thu Feb 07 00:00:00 EST 2002 · OSTI ID:662008