skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Field test and evaluation of the IAEA coincidence collar for the measurement of unirradiated BWR fuel assemblies

Technical Report ·
DOI:https://doi.org/10.2172/6614438· OSTI ID:6614438

The neutron coincidence counter has been field tested and evaluated for the measurement of boiling-water-reactor (BWR) fuel assemblies at the ASEA-ATOM Fuel Fabrication Facility. The system measures the /sup 235/U content per unit length of full fuel assemblies using neutron interrogation and coincidence counting. The /sup 238/U content is measured in the passive mode without the AmLi neutron interrogatioin source. The field tests included both standard production movable fuel rods to investigate enrichment and absorber variations. Results gave a response standard deviation of 0.9% for the active case and 2.1% for the passive case in 1000-s measurement times. 10 figures, 2 tables.

Research Organization:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
6614438
Report Number(s):
LA-9375-MS; ISPO-174; ON: DE83005603
Resource Relation:
Other Information: Portions of document are illegible. Printed copy available until stock is exhausted
Country of Publication:
United States
Language:
English