Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

A multi-channel waveform digitizer system

Conference · · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA)
OSTI ID:6609277
;  [1]
  1. Lawrence Berkeley Lab., CA (USA)
The authors report on the design and performance of a multichannel waveform digitizer system for use with the Multiple Sample Ionization Chamber (MUSIC) Detector at the Bevalac. 128 channels of 20 MHz Flash ADC plus 256 word deep memory are housed in a single crate. Digital thresholds and hit pattern logic facilitate zero suppression during readout which is performed over a standard VME bus.
DOE Contract Number:
AC03-76SF00098
OSTI ID:
6609277
Report Number(s):
CONF-900143--
Conference Information:
Journal Name: IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA) Journal Volume: 37:2
Country of Publication:
United States
Language:
English