Testing of laminar flow, HEPA filter, clean installations at Mount Facility

Conference ·
OSTI ID:6605269

The essentials needed to operate and maintain a good laminar flow, HEPA filter, clean room program are: testing and certification of the clean enclosures, operations correctly placed within the clean enclosures, and people awareness of clean enclosure procedures. The methods used for the testing and certification program of clean enclosures (clean benches and clean rooms) at Mound Facility are described. The main topics covered are: air velocity test; HEPA filter integrity test; particle count test; and philosophy for these tests.