Testing of laminar flow, HEPA filter, clean installations at Mount Facility
Conference
·
OSTI ID:6605269
The essentials needed to operate and maintain a good laminar flow, HEPA filter, clean room program are: testing and certification of the clean enclosures, operations correctly placed within the clean enclosures, and people awareness of clean enclosure procedures. The methods used for the testing and certification program of clean enclosures (clean benches and clean rooms) at Mound Facility are described. The main topics covered are: air velocity test; HEPA filter integrity test; particle count test; and philosophy for these tests.
- Research Organization:
- Mound Facility, Miamisburg, OH (USA)
- DOE Contract Number:
- AC04-76DP00053
- OSTI ID:
- 6605269
- Report Number(s):
- MLM-2800(OP); CONF-810505-2
- Country of Publication:
- United States
- Language:
- English
Similar Records
Decontamination of HEPA filters. Quarterly report, October, November, December 1976
HEPA filter jointer
Experimental investigation of in situ cleanable HEPA filter
Technical Report
·
Thu Dec 30 23:00:00 EST 1976
·
OSTI ID:495713
HEPA filter jointer
Technical Report
·
Sat Jan 31 23:00:00 EST 1998
·
OSTI ID:650221
Experimental investigation of in situ cleanable HEPA filter
Conference
·
Thu Jul 01 00:00:00 EDT 1999
·
OSTI ID:20003314