Summary of the ultrafiltration, reverse osmosis, and adsorbents project

Technical Report ·
OSTI ID:6595175

The design for a medium-size (40 gal/min) ultrafiltration (UF) membrane unit includes a schematic diagram, capital and operating costs, a list and discussion of the radioisotopes tested and the results achieved, operating parameters, and characteristics of the available membrane configurations. The plant design for a reverse osmosis (RO) membrane unit includes a conceptual diagram, specifications for a RO unit producing 40 gal/min of permeated product, a list of radioisotopes tested on RO units and the rejections achieved, a discussion of the principal of RO, a discussion of the upper limits of cation and anion concentrations (there are no lower limits), a discussion of membrane configurations and porosities, a discussion of factors affecting membranes, a section on calculating the membrane area needed for a particular application, and capital and operating cost calculations. The design for an ion-exchange pilot plant includes a schematic diagram; flow, resin, and column specifications; impurity limits; and operating and capital costs. A short theoretical discussion and process description are also included. The design retains flexibility so that application to a specific stream can be determined.

Research Organization:
Monsanto Research Corp., Miamisburg, OH (USA). Mound
DOE Contract Number:
AC04-76DP00053
OSTI ID:
6595175
Report Number(s):
MLM-3033; ON: DE83005635
Country of Publication:
United States
Language:
English