Improving dust and methane control

Book ·
OSTI ID:6592853

This paper presents a number of techniques for controlling dust and methane during the headgate cutout of retreating longwall sections that use antitropal ventilation (headgate to tailgate). Some of these techniques are effective for both methane and dust control, while others are effective for only one or the other. The techniques include the gob curtain, the walkway curtain, stage-loader-crusher control, and the wing curtain. Each improves the health and safety of workers and is economically feasible in hardware cost, setup cost, and maintenance.