Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Mixer pump test plan for double shell tank AZ-101

Technical Report ·
DOI:https://doi.org/10.2172/659250· OSTI ID:659250
Westinghouse Hanford Company has undertaken the task to develop and demonstrate a method of retrieval for double-shell tank (DST)waste. Mixer pumps were chosen as the planned method of retrieval for the DSTs, based on engineering technology studies,past experience with hydraulic sluicing at the Hanford Site, and experience with mixer pumps at the Westinghouse Savannah River Site. This document outlines a test plan to demonstrate the ability of two 300 hp mixer pumps installed in the AZ-101 tank to mobilize waste.
Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
659250
Report Number(s):
WHC-SD-WM-PTP--027-Rev.2; ON: DE98054384; BR: EW3130010
Country of Publication:
United States
Language:
English

Similar Records

Mixer pump test plan for double-shell tank AZ-101. Revision 1
Technical Report · Wed Jan 31 23:00:00 EST 1996 · OSTI ID:483371

Mixer pump test plan for double shell tank AZ-101
Technical Report · Wed May 12 00:00:00 EDT 1999 · OSTI ID:782373

SAFETY ANALYSIS FOR TANK 241-AZ-101 MIXER PUMP PROCESS TEST
Technical Report · Mon Jun 09 00:00:00 EDT 1997 · OSTI ID:963064