Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Testing of safety-related nuclear power plant equipment at the Central Receiver Test Facility

Technical Report ·
OSTI ID:6591610
The use of a solar energy facility for simulating the thermal environment (heat flux) produced as a result of hydrogen burns in a full-scale reactor containment building is described. Using a heat flux profile developed from calculations performed by the HECTR computer code, the Central Receiver Test Facility simulated the multiple burn thermal environment which HECTR predicted would result from the deliberate ignition of hydrogen generated by an S/sub 2/D accident. Functioning specimens of reactor monitoring and safety system equipment were exposed to this environment. Results of the equipment performance and temperature response are presented.
Research Organization:
Sandia National Labs., Albuquerque, NM (USA)
DOE Contract Number:
AC04-76DP00789
OSTI ID:
6591610
Report Number(s):
NUREG/CR-3776; SAND-83-1960; ON: TI85001605
Country of Publication:
United States
Language:
English