Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Safety criteria for organic watch list tanks at the Hanford Site

Technical Report ·
DOI:https://doi.org/10.2172/658874· OSTI ID:658874

This document reviews the hazards associated with the storage of organic complexant salts in Hanford Site high-level waste single- shell tanks. The results of this analysis were used to categorize tank wastes as safe, unconditionally safe, or unsafe. Sufficient data were available to categorize 67 tanks; 63 tanks were categorized as safe, and four tanks were categorized as conditionally safe. No tanks were categorized as unsafe. The remaining 82 SSTs lack sufficient data to be categorized.Historic tank data and an analysis of variance model were used to prioritize the remaining tanks for characterization.

Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
658874
Report Number(s):
WHC-SD-WM-SARR--033-Rev.1; ON: DE98058204; BR: EW3120071
Country of Publication:
United States
Language:
English

Similar Records

Preliminary safety criteria for organic watch list tanks at the Hanford site
Technical Report · Tue Oct 31 23:00:00 EST 1995 · OSTI ID:449830

Resolving the Ferrocyanide Safety Issue at the Hanford Site
Conference · Mon Jan 31 23:00:00 EST 1994 · OSTI ID:10144089

Assessment of the potential for ferrocyanide propagating reaction accidents