The experience gained and lessons learned from the 6-kW grid-integrated Wind Energy Conversion System (WECS) demonstration at Naval Station, Treasure Island, San Francisco Bay are detailed. The objective of this demonstration was to develop operating experience and maintenance information on the 6-kW WECS using a combination of permanent magnet alternator with a line commutated synchronous inverter. The on-site measurements conducted during the demonstation indicate that the WECS site has annual average windspeeds of about 8 to 10 mph. The test results to data indicate a satisfactory performance of the WECS except for two failures involving arcing at the electrical terminals located on the yaw shaft. Due to wind characteristics encountered at the site, the performance data collected to date are at windspeeds of 20 mph or lower. For evaluating the WECS performance at all windspeeds, location at a windier site with annual average windspeeds of 14 mph or higher is recommended.
- Research Organization:
- Naval Civil Engineering Lab., Port Hueneme, CA (USA)
- OSTI ID:
- 6588643
- Report Number(s):
- AD-A-119389/5
- Country of Publication:
- United States
- Language:
- English
Similar Records
20-kw wind energy conversion system (WECS) at the Marine Corps Air Station, Kaneohe, Hawaii. Report for September 1978-December 1981
Public health assessment for Treasure Island Naval Station, Hunters Point Annex, San Francisco, San Francisco County, California, Region 9. Cerclis No. CA1170090087. Final report
Enertech 15-kW wind-system development. Phase I. Design and Analysis. Volume II. Technical report
Technical Report
·
Fri Dec 31 23:00:00 EST 1982
·
OSTI ID:5759125
Public health assessment for Treasure Island Naval Station, Hunters Point Annex, San Francisco, San Francisco County, California, Region 9. Cerclis No. CA1170090087. Final report
Technical Report
·
Fri Sep 30 00:00:00 EDT 1994
·
OSTI ID:7063610
Enertech 15-kW wind-system development. Phase I. Design and Analysis. Volume II. Technical report
Technical Report
·
Tue Sep 01 00:00:00 EDT 1981
·
OSTI ID:5280931
Related Subjects
17 WIND ENERGY
170602* -- Wind Energy Engineering-- Turbine Design & Operation
ALTERNATORS
ELECTRIC GENERATORS
ELECTRICAL EQUIPMENT
EQUIPMENT
INVERTERS
MACHINERY
MAGNETS
MAINTENANCE
PACIFIC OCEAN
PERFORMANCE TESTING
PERMANENT MAGNETS
POWER RANGE 1-10 KW
SAN FRANCISCO BAY
SEAS
SURFACE WATERS
TESTING
TURBINES
TURBOMACHINERY
WIND TURBINES
170602* -- Wind Energy Engineering-- Turbine Design & Operation
ALTERNATORS
ELECTRIC GENERATORS
ELECTRICAL EQUIPMENT
EQUIPMENT
INVERTERS
MACHINERY
MAGNETS
MAINTENANCE
PACIFIC OCEAN
PERFORMANCE TESTING
PERMANENT MAGNETS
POWER RANGE 1-10 KW
SAN FRANCISCO BAY
SEAS
SURFACE WATERS
TESTING
TURBINES
TURBOMACHINERY
WIND TURBINES