Title: Summary and analsysis of the 1986 ORNL personnel dosimetry intercomparison study

Technical Report ·
DOI:https://doi.org/10.2172/6585118· OSTI ID:6585118

The Twelfth Personnel Dosimetry Intercomparison Study was conducted at the Oak Ridge National Laboratory (ORNL) during April 14 to 17, 1986. Objectives of this study were to determine neutron dosimeter performance characteristics at neutron dose equivalent levels near the minimum specified for accreditation testing programs and to provide several radiation fields different from those that have been considered in prior ORNL intercomparisons. Dosimeter badges from 49 participating organizations were mounted on Lucite block phantoms and exposed to six mixed-radiation fields (five using the Health Physics Research Reactor and one using a PuBe source) with neutron dose equivalents of about 1.5 mSv and gamma dose equivalents between 0.04 and 5.37 mSv. Results of this study indicated that participants had no difficulty obtaining measurable indication of neutron exposure at dose equivalent levels of about 1.5 mSv. Average neutron results for all dosimeter types were within approximately 60% of reference values with hard spectra being more accurately measured than soft spectra. Considering all irradiations, albedo and direct interaction TLD systems provided about the same performance characteristics. With regard to precision, about 58% of the reported neutron results had single standard deviations within 10% at the means which indicates that precision was not a problem relative to accuracy for over half of the participants. Average gamma results varied from 0.98 to 2.22 times reference values for all exposures with TLD systems being more accurate than film. Some participants, especially those using film, had difficulty obtaining measurable indication of gamma exposures at dose equivalent levels lower than 0.09 mSv. About 69% of all neutron results and 77% of all gamma results met regulatory standards for measurement accuracy and approximately 65% of all neutron data satisfied national dosimetry accreditation criteria for accuracy plus precision. 18 refs., 1 fig., 30 tabs.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
DOE Contract Number:
AC05-84OR21400
OSTI ID:
6585118
Report Number(s):
ORNL-6378; ON: DE87009770
Resource Relation:
Other Information: Portions of this document are illegible in microfiche products. Original copy available until stock is exhausted
Country of Publication:
United States