Compressed-air energy-storage preliminary design and site-development program in an aquifer. Volume 6. Balance of plant design. Final report
Technical Report
·
OSTI ID:6584862
A study was performed to investigate the behavior and suitability of an aquifer-based compressed-air energy storage (CAES) plant. The study, which was sponsored by the Department of Energy and the Electric Power Research Institute, established methodologies and preliminary design procedures for developing, designing, constructing, and operating a CAES facility utilizing an aquifer storage formation. Volume 6 forms a part of the final report describing the information derived from the study. Volume 6 contains the balance of plant design considerations for a CAES plant. More specifically, this volume provides the design of the aboveground facilities including well locations, fuel oil storage, switchyards, facility access, plant and equipment arrangement, and process flow diagrams.
- Research Organization:
- Sargent and Lundy, Chicago, IL (USA); Public Service Co. of Indiana, Inc., Plainfield (USA)
- DOE Contract Number:
- AC02-78ET29232
- OSTI ID:
- 6584862
- Report Number(s):
- EPRI-EM-2351-Vol.6; ON: DE83005729
- Country of Publication:
- United States
- Language:
- English
Similar Records
Compressed-air energy storage: preliminary design and site development program in an aquifer. Volume VI. Balance of plant design. Final report
Compressed-air energy-storage preliminary design and site development program in an aquifer. Volume VIII. Aquifer flow code simulation. Final report
Compressed-air energy storage: preliminary design and site development program in an aquifer. Volume VIII. Aquifer flow code simulation. Final report
Technical Report
·
Fri Jul 31 00:00:00 EDT 1981
·
OSTI ID:5831445
Compressed-air energy-storage preliminary design and site development program in an aquifer. Volume VIII. Aquifer flow code simulation. Final report
Technical Report
·
Tue Nov 30 23:00:00 EST 1982
·
OSTI ID:6584861
Compressed-air energy storage: preliminary design and site development program in an aquifer. Volume VIII. Aquifer flow code simulation. Final report
Technical Report
·
Fri Jul 31 00:00:00 EDT 1981
·
OSTI ID:5831425
Related Subjects
20 FOSSIL-FUELED POWER PLANTS
200107 -- Fossil-Fueled Power Plants-- Off-Peak Energy Storage-- (1980-)
25 ENERGY STORAGE
250200* -- Energy Storage-- Compressed & Liquified Gas
AQUIFERS
COMPRESSED AIR ENERGY STORAGE
COMPRESSED AIR STORAGE POWER PLANTS
DESIGN
ENERGY STORAGE
FEDERAL REGION V
ILLINOIS
NORTH AMERICA
PEAKING POWER PLANTS
POWER PLANTS
SPECIFICATIONS
STORAGE
USA
200107 -- Fossil-Fueled Power Plants-- Off-Peak Energy Storage-- (1980-)
25 ENERGY STORAGE
250200* -- Energy Storage-- Compressed & Liquified Gas
AQUIFERS
COMPRESSED AIR ENERGY STORAGE
COMPRESSED AIR STORAGE POWER PLANTS
DESIGN
ENERGY STORAGE
FEDERAL REGION V
ILLINOIS
NORTH AMERICA
PEAKING POWER PLANTS
POWER PLANTS
SPECIFICATIONS
STORAGE
USA