PACER -- A fast running computer code for the calculation of short-term containment/confinement loads following coolant boundary failure. Volume 1: Code models and correlations
A fast running and simple computer code has been developed to calculate pressure loadings inside light water reactor containments/confinements under loss-of-coolant accident conditions. PACER was originally developed to calculate containment/confinement pressure and temperature time histories for loss-of-coolant accidents in Soviet-designed VVER reactors and is relevant to the activities of the US International Nuclear Safety Center. The code employs a multicompartment representation of the containment volume and is focused upon application to early time containment phenomena during and immediately following blowdown. Flashing from coolant release, condensation heat transfer, intercompartment transport, and engineered safety features are described using best estimate models and correlations often based upon experiment analyses. Two notable capabilities of PACER that differ from most other containment loads codes are the modeling of the rates of steam and water formation accompanying coolant release as well as the correlations for steam condensation upon structure.
- Research Organization:
- Argonne National Lab., IL (United States)
- Sponsoring Organization:
- USDOE Assistant Secretary for Nuclear Energy, Washington, DC (United States)
- DOE Contract Number:
- W-31109-ENG-38
- OSTI ID:
- 658423
- Report Number(s):
- ANL-NT--40; ON: DE98005659
- Country of Publication:
- United States
- Language:
- English
Similar Records
PACER -- A fast running computer code for the calculation of short-term containment/confinement loads following coolant boundary failure. Volume 2: User information
Pressure loadings of Soviet-designed VVER (Water-Cooled, Water-Moderated Energy Reactor) reactor release mitigation structures from large-break LOCAs
Containment pressure assessment using the COBRA-NC computer code
Technical Report
·
Sun Jun 01 00:00:00 EDT 1997
·
OSTI ID:515631
Pressure loadings of Soviet-designed VVER (Water-Cooled, Water-Moderated Energy Reactor) reactor release mitigation structures from large-break LOCAs
Conference
·
Sat Dec 31 23:00:00 EST 1988
·
OSTI ID:5530200
Containment pressure assessment using the COBRA-NC computer code
Conference
·
Wed Dec 31 23:00:00 EST 1986
· Trans. Am. Nucl. Soc.; (United States)
·
OSTI ID:6808286