Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Criticality safety assessment of tank 241-C-106 remediation

Technical Report ·
DOI:https://doi.org/10.2172/657843· OSTI ID:657843

A criticality safety assessment was performed in support of Project 320 for the retrieval of waste from tank 241-C-106 to tank 241-AY-102. The assessment was performed by a multi-disciplined team consisting of expertise covering the range of nuclear engineering, plutonium and nuclear waste chemistry,and physical mixing hydraulics. Technical analysis was performed to evaluate the physical and chemical behavior of fissile material in neutralized Hanford waste as well as modeling of the fluid dynamics for the retrieval activity. The team has not found evidence of any credible mechanism to attain neutronic criticality in either tank and has concluded that a criticality accident is incredible.

Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
657843
Report Number(s):
WHC-SD-W320-CSA--001; ON: DE98058278; BR: EW3130010; CNN: DE-AC06-96RL13200
Country of Publication:
United States
Language:
English