Title: Calorimetric fission product decay heat measurements for /sup 239/Pu, /sup 233/U, and /sup 235/U

Technical Report ·
OSTI ID:6577911

A fast-response cryogenic boil-off calorimeter was used to measure decay heat from the products of thermal fission of /sup 239/Pu, /sup 233/U, and /sup 235/U. Data are presented for cooling times between 20 and 10/sup 5/ s following a 2 x 10/sup 4/-s irradiation at constant thermal neutron flux. The experimental uncertainty (1 sigma) was 3 to 4% for /sup 239/Pu, approximately 5% for /sup 233/U, and approximately 2% for /sup 235/U. The average percent deviation of the experimental data points from summation calculations using the ENDF/B-IV data base was +9.7% for /sup 239/Pu, +4.2% for /sup 233/U, and +0.5% for /sup 235/U. The agreement between experiment and calculation is satisfactory except in the case of /sup 239/Pu, where the deviation exceeds the combined uncertainties in the experiment and the calculation. The difference between experiment and summation calculation for /sup 239/Pu is believed to be significant, but its source has not been identified. 4 figures, 12 tables.

Research Organization:
Los Alamos Scientific Lab., NM (USA)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
6577911
Report Number(s):
NUREG/CR-0349; LA-7452-MS; TRN: 79-001615