High heat generation safety issue in tank 241-C-106

Technical Report ·
DOI:https://doi.org/10.2172/657698· OSTI ID:657698

A `White` paper was written on the High Heat Generation Safety Issue in Tank 241-C-106. The issue is if tank 241-C-106 should start leaking, the lack of alternative cooling methods will require continued addition of water and thereby possibly increase the amount of leakage to the ground. If the current methods of cooling the tank are stopped, the sludge and concrete structure will heat to temperatures greater than established limits and may cause structural damage, leading to dome collapse and possibly an unacceptable radioactive release to the environment. Potential approaches to the resolution of this issue were evaluated, and waste retrieval by sluicing and transfer to a double-shell tank was selected. The paper gives background information on the tank and an assessment of the issue and its resolution, with references to support the paper.

Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
657698
Report Number(s):
WHC-SD-WM-ER--586; ON: DE98057647; BR: EW3135040
Country of Publication:
United States
Language:
English

Similar Records

Nonradioactive air emissions notice of construction, Project W-320, 241-C-106 tank sluicing
Technical Report · Tue Jan 27 23:00:00 EST 1998 · OSTI ID:353266

High-heat tank safety issues evaluation
Technical Report · Mon May 10 00:00:00 EDT 1993 · OSTI ID:10170322

Tank 241-C-106 waste retrieval sluicing system process control plan
Technical Report · Sat Jul 25 00:00:00 EDT 1998 · OSTI ID:362429