Development of submicron particle size classification and collection techniques for nuclear facility off-gas streams. [Diffusion battery and electrofluidized bed]

Technical Report ·
DOI:https://doi.org/10.2172/6566429· OSTI ID:6566429
High efficiency particulate air (HEPA) filters are an essential part of nuclear facility off-gas cleanup systems. However, HEPA-rated sampling filters are not the most appropriate samplers for the particle penetrating off-gas cleanup systems. Previous work at the Idaho Chemical Processing Plant (ICPP) estimated perhaps 5% of the radioactivity that challenged sampling filters penetrated them in the form of submicron particles - typically less than 0.2 microns. Accordingly, to evaluate these penetrating aerosols more fully, a suitable robust monitoring system for size differentiation and measurement of submicron particles was developed. A literature survey revealed that the diffusion battery was the best choice for particle size classification and that the electrofluidized bed was the best method for particle collection in ICPP off-gas streams. This report describes the laboratory study and in-plant demonstration of these two techniques.
Research Organization:
Exxon Nuclear Idaho Co., Inc., Idaho Falls (USA)
DOE Contract Number:
AC07-79ID01675
OSTI ID:
6566429
Report Number(s):
ENICO-1076
Country of Publication:
United States
Language:
English

Similar Records

Evaluation of submicron particle size classification and collection techniques for nuclear facility off-gas streams
Technical Report · Wed Aug 01 00:00:00 EDT 1979 · OSTI ID:6026334

Development of HEPA filter retention-efficiency monitor
Technical Report · Fri Oct 01 00:00:00 EDT 1982 · OSTI ID:5051365

Continuous plutonium monitor for nuclear facility off-gas streams
Technical Report · Wed Oct 01 00:00:00 EDT 1980 · OSTI ID:5039203