Heat exchanger fouling in a coal-fired fluidized bed combustor
Journal Article
·
· Am. Soc. Mech. Eng., (Pap.); (United States)
OSTI ID:6559185
Operating experience with fouling of a finned tube flue gas heat exchanger is described. The heat exchanger is located in the convection pass of an industrial type, pilot-sized coal-fired atmospheric fluidized bed combustor using a forced circulation water/glycol coolant loop. Values of heat transfer coefficient were calculated from actual run data, and compared with design values. It was found that condensation on the fins caused excessive fouling, due to accumulation of elutriated limestone and coal ash. Various solutions were tried, and the results of each attempt are described.
- Research Organization:
- University of Kentucky Institute for Mining and Minerals Research P.O. Box 13015, Iron Works Pike Lexington, Kentucky
- OSTI ID:
- 6559185
- Journal Information:
- Am. Soc. Mech. Eng., (Pap.); (United States), Journal Name: Am. Soc. Mech. Eng., (Pap.); (United States) Vol. 83-HT-90; ISSN ASMSA
- Country of Publication:
- United States
- Language:
- English
Similar Records
Hot gas heat exchanger fired from the fluidized bed wood combustor
Mathematical modelling of coal fired fluidized bed combustors
Fouling reduction characteristics of a no-distributor-fluidized-bed heat exchanger for flue gas heat recovery
Conference
·
Thu Aug 01 00:00:00 EDT 1985
· Energy Technol. (Wash., D.C.); (United States)
·
OSTI ID:5765315
Mathematical modelling of coal fired fluidized bed combustors
Conference
·
Sun Nov 30 23:00:00 EST 1980
· Alternative Energy Sources; (United States)
·
OSTI ID:5058561
Fouling reduction characteristics of a no-distributor-fluidized-bed heat exchanger for flue gas heat recovery
Journal Article
·
Tue Jul 01 00:00:00 EDT 2008
· Heat Transfer Engineering
·
OSTI ID:21073780
Related Subjects
42 ENGINEERING
420400* -- Engineering-- Heat Transfer & Fluid Flow
ANTIFOULANTS
CIRCULATING SYSTEMS
COMBUSTORS
COOLANT LOOPS
COOLING SYSTEMS
DATA
ENERGY SYSTEMS
ENERGY TRANSFER
EXPERIMENTAL DATA
FLUE GAS
FLUIDIZED-BED COMBUSTORS
FOULING
GASEOUS WASTES
HEAT EXCHANGERS
HEAT TRANSFER
INFORMATION
NUMERICAL DATA
OPERATION
TUBES
WASTES
420400* -- Engineering-- Heat Transfer & Fluid Flow
ANTIFOULANTS
CIRCULATING SYSTEMS
COMBUSTORS
COOLANT LOOPS
COOLING SYSTEMS
DATA
ENERGY SYSTEMS
ENERGY TRANSFER
EXPERIMENTAL DATA
FLUE GAS
FLUIDIZED-BED COMBUSTORS
FOULING
GASEOUS WASTES
HEAT EXCHANGERS
HEAT TRANSFER
INFORMATION
NUMERICAL DATA
OPERATION
TUBES
WASTES