Evacuated tube collectors are not flat plates

Conference · · Proc. Annu. Meet. - Am. Sect. Int. Sol. Energy Soc.; (United States)
OSTI ID:6547930
Explicit test results are provided which hopefully will lead to additional test procedures to make ASHRAE 93-77 and NBSIR 1305A acceptable for testing evacuated tube collectors and to promote a standard procedure for utilizing ASHRAE 93-77 test results to assist solar system designers in making proper application of the data. The appropriate choice of collectors and collector array size is generally based on the thermal performance of collectors which have been tested to the current baseline testing standard, ASHRAE 93-77. Unfortunately, the standard does not specify proper utilization of the test results, and quite often the incident angle modifier is ignored in sizing collector array arrangements, resulting in undersized arrays for flat plates and possible oversized arrays with evacuated tubes.
OSTI ID:
6547930
Report Number(s):
CONF-800604-P2
Conference Information:
Journal Name: Proc. Annu. Meet. - Am. Sect. Int. Sol. Energy Soc.; (United States) Journal Volume: 3.1
Country of Publication:
United States
Language:
English

Similar Records

Evaluation of all-day-efficiency for selected flat plate and evacuated tube collectors
Technical Report · Tue Sep 01 00:00:00 EDT 1981 · OSTI ID:5350270

Understanding flat plate solar collector efficiency
Journal Article · Thu Dec 31 23:00:00 EST 1981 · Sol. Mag.; (United States) · OSTI ID:5618311

Uncertainty in determining thermal performance of liquid-heating flat-plate solar collectors
Journal Article · Fri May 01 00:00:00 EDT 1981 · J. Sol. Energy Eng.; (United States) · OSTI ID:5747304