An interactive execution capability has been developed for the RELAP5 code which permits it to be used as a Nuclear Plant Analyzer. This capability has been demonstrated using a simplified primary and secondary loop model of a PWR. A variety of loss-of-feed-water accidents have been simulated using this model. The computer execution time on a CDC Cyber 176 is one half of the transient simulation time so that the results can be displayed in real time. The results of the demonstration problems are displayed in digital form on a color schematic of the plant model using a Textronics 4027 CRT terminal. The interactive feature allows the user to enter commands in much the same manner as a reactor operator.
Research Organization:
EG and G Idaho, Inc., Idaho Falls (USA)
DOE Contract Number:
AC07-76ID01570
OSTI ID:
6546028
Report Number(s):
EGG-M-16982; CONF-821103-74; ON: DE83005394
Country of Publication:
United States
Language:
English