Double-blind evaluation of the DKL LifeGuard Model 2

Technical Report ·
DOI:https://doi.org/10.2172/654000· OSTI ID:654000
On March 20, 1998, Sandia National Laboratories performed a double-blind test of the DKL LifeGuard human presence detector and tracker. The test was designed to allow the device to search for individuals well within the product`s published operational parameters. The Test Operator of the DKL LifeGuard was provided by the manufacturer and was a high-ranking member of DKL management. The test was developed and implemented to verify the performance of the device as specified by the manufacturer. The device failed to meet its published specifications and it performed no better than random chance.