Title: Double-blind evaluation of the DKL LifeGuard Model 2

Abstract

On March 20, 1998, Sandia National Laboratories performed a double-blind test of the DKL LifeGuard human presence detector and tracker. The test was designed to allow the device to search for individuals well within the product`s published operational parameters. The Test Operator of the DKL LifeGuard was provided by the manufacturer and was a high-ranking member of DKL management. The test was developed and implemented to verify the performance of the device as specified by the manufacturer. The device failed to meet its published specifications and it performed no better than random chance.

Authors:
; ;
Publication Date:
Research Org.:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
Sponsoring Org.:
USDOE Assistant Secretary for Environment, Safety, and Health, Washington, DC (United States)
OSTI Identifier:
654000
Report Number(s):
SAND-98-0977
ON: DE98005262; TRN: 98:010294
DOE Contract Number:  
AC04-94AL85000
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: May 1998
Country of Publication:
United States
Language:
English
Subject:
05 NUCLEAR FUELS; INTRUSION DETECTION SYSTEMS; HUMAN INTRUSION; PERFORMANCE TESTING; SECURITY; SAFEGUARDS

Citation Formats

Murray, D W, Spencer, F W, and Spencer, D D. Double-blind evaluation of the DKL LifeGuard Model 2. United States: N. p., 1998. Web. doi:10.2172/654000.
Murray, D W, Spencer, F W, & Spencer, D D. Double-blind evaluation of the DKL LifeGuard Model 2. United States. https://doi.org/10.2172/654000
Murray, D W, Spencer, F W, and Spencer, D D. 1998. "Double-blind evaluation of the DKL LifeGuard Model 2". United States. https://doi.org/10.2172/654000. https://www.osti.gov/servlets/purl/654000.
@article{osti_654000,
title = {Double-blind evaluation of the DKL LifeGuard Model 2},
author = {Murray, D W and Spencer, F W and Spencer, D D},
abstractNote = {On March 20, 1998, Sandia National Laboratories performed a double-blind test of the DKL LifeGuard human presence detector and tracker. The test was designed to allow the device to search for individuals well within the product`s published operational parameters. The Test Operator of the DKL LifeGuard was provided by the manufacturer and was a high-ranking member of DKL management. The test was developed and implemented to verify the performance of the device as specified by the manufacturer. The device failed to meet its published specifications and it performed no better than random chance.},
doi = {10.2172/654000},
url = {https://www.osti.gov/biblio/654000}, journal = {},
number = ,
volume = ,
place = {United States},
year = {1998},
month = {5}
}