High-pressure transition boiling in internal flows

Journal Article · · J. Heat Transfer; (United States)
DOI:https://doi.org/10.1115/1.3248110· OSTI ID:6536827
Transition boiling heat transfer was studied for the case of internal flow of high-pressure water. Transition boiling results were determined from measurements from 138 steady-state tests conducted in a temperature-controlled facility. Water flowed vertically upward inside a tube with inside diameter = 10.1 mm and vertical length = 13.1 m, as it was heated by liquid sodium flowing countercurrent in a surrounding annulus. The water parameter range of the experiments was pressure 7--15.3 MPa and mass flux 0.7--3.2 Mg/m/sup 2/xs. A mathematical model was developed that predicted the transition boiling heat transfer coefficient well over the entire parameter range.
Research Organization:
Department of Mechanical Engineering, University of Illinois at Chicago, Chicago, IL 60680
OSTI ID:
6536827
Journal Information:
J. Heat Transfer; (United States), Journal Name: J. Heat Transfer; (United States) Vol. 109:2; ISSN JHTRA
Country of Publication:
United States
Language:
English

Similar Records

Critical heat flux experiments and correlation in a long, sodium-heated tube
Journal Article · Sat Jan 31 23:00:00 EST 1981 · J. Heat Transfer; (United States) · OSTI ID:6252145

Transition boiling models in heat exchangers
Journal Article · Mon Aug 01 00:00:00 EDT 1988 · J. Heat Transfer; (United States) · OSTI ID:7084766

Characteristics of transition boiling in sodium-heated steam generator tubes