Combustion modification Nox controls for utility boilers. Volume I: tangential coal-fired unit field test. Final report Jul 78-Jul 79
Technical Report
·
OSTI ID:6535832
The report gives results of an environmental assessment field testing program on a tangential-coal-fired utility boiler. The aim of the program was to measure multimedia emissions changes as a result of applying combustion modification NOx control. Emissions of trace elements, organic materials, sulfur species, SO2, NOx, CO, and particulate matter were measured. These emissions were compared under normal and low-NOx operating conditions. Source operating data were also analyzed so that changes in operating parameters and efficiency could be assessed. The test were conducted on TVA's Kingston Steam Plant, Unit 6, a 180-MW, pulverized-coal, tangentially fired, electric utility boiler with a rated capacity of 582 Mg/hr (1.28 million lb/hr) steam. Burners-out-of-service and biased-burner firing were used for NOx control.
- Research Organization:
- Acurex Corp., Mountain View, CA (USA). Energy and Environmental Div.
- OSTI ID:
- 6535832
- Report Number(s):
- PB-82-227265
- Country of Publication:
- United States
- Language:
- English
Similar Records
Industrial boiler combustion modification Nox controls. Volume II: stoker-coal-fired boiler field test - Site A. Final report Jul 78-Jul 79
Evaluation of NOX emissions from TVA coal-fired power plants
Analysis test data for NOx control in coal-fired utility boilers. Final task report, Jul 1974--Oct 1975
Technical Report
·
Wed Jul 01 00:00:00 EDT 1981
·
OSTI ID:6381741
Evaluation of NOX emissions from TVA coal-fired power plants
Technical Report
·
Mon Dec 31 23:00:00 EST 1990
·
OSTI ID:5284966
Analysis test data for NOx control in coal-fired utility boilers. Final task report, Jul 1974--Oct 1975
Technical Report
·
Fri Oct 01 00:00:00 EDT 1976
·
OSTI ID:7108611
Related Subjects
20 FOSSIL-FUELED POWER PLANTS
200202* -- Fossil-Fueled Power Plants-- Waste Management-- Noxious Gas & Particulate Emissions
AIR POLLUTION CONTROL
BOILERS
CARBON COMPOUNDS
CARBON MONOXIDE
CARBON OXIDES
CHALCOGENIDES
COMBUSTION CONTROL
COMBUSTION PRODUCTS
CONTROL
FIELD TESTS
FLUE GAS
FOSSIL-FUEL POWER PLANTS
GASEOUS WASTES
INDUSTRIAL WASTES
KINGSTON STEAM PLANT
NITROGEN COMPOUNDS
NITROGEN OXIDES
OXIDES
OXYGEN COMPOUNDS
PARTICLES
PARTICULATES
POLLUTION CONTROL
POWER PLANTS
SULFUR COMPOUNDS
SULFUR DIOXIDE
SULFUR OXIDES
TESTING
THERMAL POWER PLANTS
TRACE AMOUNTS
WASTES
200202* -- Fossil-Fueled Power Plants-- Waste Management-- Noxious Gas & Particulate Emissions
AIR POLLUTION CONTROL
BOILERS
CARBON COMPOUNDS
CARBON MONOXIDE
CARBON OXIDES
CHALCOGENIDES
COMBUSTION CONTROL
COMBUSTION PRODUCTS
CONTROL
FIELD TESTS
FLUE GAS
FOSSIL-FUEL POWER PLANTS
GASEOUS WASTES
INDUSTRIAL WASTES
KINGSTON STEAM PLANT
NITROGEN COMPOUNDS
NITROGEN OXIDES
OXIDES
OXYGEN COMPOUNDS
PARTICLES
PARTICULATES
POLLUTION CONTROL
POWER PLANTS
SULFUR COMPOUNDS
SULFUR DIOXIDE
SULFUR OXIDES
TESTING
THERMAL POWER PLANTS
TRACE AMOUNTS
WASTES