Energy savings with solid-state ballasted high-pressure sodium lamps
Conference
·
OSTI ID:6525630
The performance of three types of solid-state ballasts used to operate high-pressure sodium lamps is discussed. Each type of solid-state ballast has been designed to operate an HPS lamp of a different wattage (150, 200, and 400 watts). The performance of these ballasts compared to standard core-coil ballasts operating the same HPS lamps shows that system efficiency improves as much as 17%. The solid-state ballasted HPS system also demonstrates excellent regulation with respect to input voltage and output power. These new ballasts can dim the HPS lamps and reduce flicker from more than 60% to less than 3%. Refitting street lighting with these new HPS systims provides an attractive return on initial capital investment.
- Research Organization:
- Lawrence Berkeley Lab., CA (USA)
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 6525630
- Report Number(s):
- LBL-12595; CONF-810590-1; ON: DE81023202
- Country of Publication:
- United States
- Language:
- English
Similar Records
Performance of electronic ballasts and lighting controllers with 34-W fluorescent lamps: Final report
Performance of electronic ballasts and other new lighting equipment: (Phase 2, The 34-watt F40 rapid start T-12 fluorescent lamp): Final report
High intensity discharge (HID) solid state ballast program: Phase I. Final report
Technical Report
·
Wed Jun 01 00:00:00 EDT 1988
·
OSTI ID:7225321
Performance of electronic ballasts and other new lighting equipment: (Phase 2, The 34-watt F40 rapid start T-12 fluorescent lamp): Final report
Technical Report
·
Sun Jan 31 23:00:00 EST 1988
·
OSTI ID:6516103
High intensity discharge (HID) solid state ballast program: Phase I. Final report
Technical Report
·
Mon Sep 01 00:00:00 EDT 1980
·
OSTI ID:6611564
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320602* -- Energy Conservation
Consumption
& Utilization-- Municipalities & Community Systems-- Public Services-- (1980-)
BALLASTS
COMMUNITIES
CONTROL
DESIGN
EFFICIENCY
ENERGY EFFICIENCY
ENERGY SYSTEMS
LIGHTING SYSTEMS
OPERATION
PAYBACK PERIOD
PERFORMANCE
RETROFITTING
320602* -- Energy Conservation
Consumption
& Utilization-- Municipalities & Community Systems-- Public Services-- (1980-)
BALLASTS
COMMUNITIES
CONTROL
DESIGN
EFFICIENCY
ENERGY EFFICIENCY
ENERGY SYSTEMS
LIGHTING SYSTEMS
OPERATION
PAYBACK PERIOD
PERFORMANCE
RETROFITTING