Intergranular attack of Alloy 600 in pressurized water reactor steam generator tubes

Journal Article · · Mater. Performance; (United States)
OSTI ID:6523145

In some steam generators, intergranular attack (IGA) has been detected on Alloy 600 tubes within or near the tubesheet crevice region. A study was undertaken to reproduce IGA in an experimental device simulating steam generator conditions. Chemical parameters and test procedures were adjusted to obtain a high concentration of alkalies in the tubesheet crevices and a representative corrosion attack of tubing materials. Millannealed (MA) Alloy 600 was the most susceptible to IGA, but a thermal treatment at 700 C decreased the amount of IGA. The least vulnerable material was an experimental MA alloy 690.

Research Organization:
Commissariat a l'Energie Atomique (CEA), Laboratoire d'Essais Technologiques de Corrosion, BP 270, 50107 Cherbourg
OSTI ID:
6523145
Journal Information:
Mater. Performance; (United States), Journal Name: Mater. Performance; (United States) Vol. 26:3; ISSN MTPFB