Title: FFTF shield and gamma ray measurements

Conference ·
OSTI ID:6519091

Shield measurements and four cycles of operating experience have shown the design and construction of radiation shields for the Fast Flux Test Facility (FFTF) reactor and plant to be satisfactory. A number of minor shield deficiencies were found and corrected. Most of these were associated with interfaces between components, each of which was satisfactory by itself. Preliminary evaluation of the shield measurements indicates satisfactory agreement with design calculations. Operator doses to date have been quite small, especially when compared to light water reactor experience.

Research Organization:
Hanford Engineering Development Lab., Richland, WA (USA)
DOE Contract Number:
AC06-76FF02170
OSTI ID:
6519091
Report Number(s):
HEDL-SA-3051-FP; CONF-840901-17; ON: DE85000772
Resource Relation:
Conference: ANS topical meeting on reactor physics and shielding, Chicago, IL, USA, 17 Sep 1984
Country of Publication:
United States