Southwest Thermal Mass Study, Tesuque Pueblo, New Mexico: the effect of envelope thermal mass on the heating energy use of eight test buildings in a high desert climate (September 1981-December 1982)
Technical Report
·
OSTI ID:6512733
Eight windowless one-room test buildings, 6.10 m square and 2.29 m high inside, were constructed on a high desert site near Tesuque Pueblo, New Mexico, to study the influence of wall dynamic heat transfer characteristics on building heating energy requirements (such influence is sometimes called the thermal mass effect). The buildings are nominally identical except for the walls, and are instrumented to record building component temperatures and heat fluxes; indoor temperature, humidity, globe temperature, and interior surface temperatures; and outdoor weather, solar data, and ground temperatures. This report presents the results from analysis of heating season data for one year. A simple method of analysis using steady-state methods on time-averaged data is derived from first principles. Energy use data for each building are correlated to weather parameters and building interior conditions, and are compared to predictions of steady-state modeling. Comfort parameters are evaluated for each building, and critically compared. In situ measurements of wall thermal properties and dynamic heat transfer characteristics are presented, including data for adobe walls.
- Research Organization:
- New Mexico Univ., Albuquerque (USA). New Mexico Energy Research and Development Inst.
- DOE Contract Number:
- AC05-84OR21400
- OSTI ID:
- 6512733
- Report Number(s):
- ORNL/Sub-80-7948/1; ON: DE85001735
- Country of Publication:
- United States
- Language:
- English
Similar Records
Southwest Thermal Mass Study: effect of envelope thermal mass on the heating energy use of eight test buildings in a high desert climate, September 1981-December 1982
Southwest thermal mass study. The effect of envelope thermal mass on the heating energy use of eight test buildings in a high desert climate. Research phase I, September 1981 through December 1982
Southwest thermal mass study, Tesuque Pueblo, New Mexico. Observation and prediction of the heating season thermal mass effect for eight test buildings with and without windows. Research Phase II, January 1983-June 1983
Technical Report
·
Sat Mar 31 23:00:00 EST 1984
·
OSTI ID:6108861
Southwest thermal mass study. The effect of envelope thermal mass on the heating energy use of eight test buildings in a high desert climate. Research phase I, September 1981 through December 1982
Technical Report
·
Sat Mar 31 23:00:00 EST 1984
·
OSTI ID:6945684
Southwest thermal mass study, Tesuque Pueblo, New Mexico. Observation and prediction of the heating season thermal mass effect for eight test buildings with and without windows. Research Phase II, January 1983-June 1983
Technical Report
·
Sat Sep 01 00:00:00 EDT 1984
·
OSTI ID:6517530