Test and evaluation of the dual-range coincidence counter at the Savannah River Plant

Technical Report ·
DOI:https://doi.org/10.2172/6511236· OSTI ID:6511236
This report describes the test and evaluation of a Los Alamos National Laboratory-designed dual-range neutron coincidence counter at the Savannah River Plant Separations Area. A variety of incoming plutonium metal and oxide shipments were assayed with the counter. Assay accuracies were 2% l sigma for pure metal, about 10% l sigma for impure metal, and 3% l sigma for oxide that was analyzed on a batch-by-batch basis.
Research Organization:
Los Alamos National Lab., NM (USA)
Sponsoring Organization:
Not Available; USDOE National Nuclear Security Administration (NNSA), Nuclear Criticality Safety Program (NCSP)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
6511236
Report Number(s):
LA-8803-MS