Estimate of emittance growth due to sychrobetatron resonance driven by dispersion in rf cavities
Technical Report
·
OSTI ID:6506338
Emittance growth by synchrobetatron resonance is estimated for the 6 GeV booster of the Advanced Hadron Facility. It is shown that the emittance growth is modest both for horizontal and vertical betatron motions if we avoid only the m = 1 resonance where the resonance condition is ..nu../sub x/ - m..nu../sub s/ = integer.