VAV system volume control using electronic strategies
Conference
·
· ASHRAE Trans.; (United States)
OSTI ID:6494369
Air volume can be measured reliably with conventional electronic differential temperature techniques. Controlling the actual outside-air minimum volume independent of the variable supply fan delivery is necessary to meet minimum ventilation and positive building pressurization requirements. Simulated exhaust-fan flow signals can be added electronically and subtracted from return-fan and outdoor-air make-up volumes to balance the pressure. Energy can be saved by admitting only the required outside-air volume and by controlling the return-air volume for variable exhaust requirements, resulting in low return-fan brake horsepower. This paper discusses control techniques applied to systems installed in the Utah area during 1984 and 1985.
- Research Organization:
- Atkinson Electronics, Inc., Salt Lake City, UT
- OSTI ID:
- 6494369
- Report Number(s):
- CONF-8606125-
- Conference Information:
- Journal Name: ASHRAE Trans.; (United States) Journal Volume: 92:2B
- Country of Publication:
- United States
- Language:
- English
Similar Records
Minimum outside air control methods for VAV systems
Outdoor air flow control for VAV systems
Ventilation air, the economy cycle, and VAV
Conference
·
Sat Dec 30 23:00:00 EST 1995
·
OSTI ID:211828
Outdoor air flow control for VAV systems
Journal Article
·
Fri Mar 31 23:00:00 EST 1995
· ASHRAE Journal
·
OSTI ID:62999
Ventilation air, the economy cycle, and VAV
Journal Article
·
Sat Oct 01 00:00:00 EDT 1994
· Heating, Piping and Air Conditioning; (United States)
·
OSTI ID:6829442
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320106* -- Energy Conservation
Consumption
& Utilization-- Building Equipment-- (1987-)
99 GENERAL AND MISCELLANEOUS
990220 -- Computers
Computerized Models
& Computer Programs-- (1987-1989)
AIR FLOW
BLOWERS
BUILDINGS
COMPUTERIZED CONTROL SYSTEMS
CONTROL
CONTROL SYSTEMS
ENERGY CONSERVATION
FEDERAL REGION VIII
FLUID FLOW
GAS FLOW
NORTH AMERICA
PRESSURE CONTROL
PRESSURIZING
SIGNALS
TEMPERATURE MEASUREMENT
USA
UTAH
VENTILATION
VOLUME
320106* -- Energy Conservation
Consumption
& Utilization-- Building Equipment-- (1987-)
99 GENERAL AND MISCELLANEOUS
990220 -- Computers
Computerized Models
& Computer Programs-- (1987-1989)
AIR FLOW
BLOWERS
BUILDINGS
COMPUTERIZED CONTROL SYSTEMS
CONTROL
CONTROL SYSTEMS
ENERGY CONSERVATION
FEDERAL REGION VIII
FLUID FLOW
GAS FLOW
NORTH AMERICA
PRESSURE CONTROL
PRESSURIZING
SIGNALS
TEMPERATURE MEASUREMENT
USA
UTAH
VENTILATION
VOLUME