Convection heat loss from a cavity receiver

Journal Article · · J. Sol. Energy Eng.; (United States)
DOI:https://doi.org/10.1115/1.3267569· OSTI ID:6476333
The total convection loss from the absorber panels of a 5MW /SUB t/ cavity receiver were measured experimentally and found to be 1.43 percent of the total heat input. Since the measured convection loss from the tests, which were influenced both by forced and free convection, is essentially equal to the loss predicted by Seiber's correlation, which accounts for free convection only, it is apparent that a cavity geometry reduces receiver convection losses significantly.
Research Organization:
Martin Marietta Denver Aerospace, Denver, CO
OSTI ID:
6476333
Journal Information:
J. Sol. Energy Eng.; (United States), Journal Name: J. Sol. Energy Eng.; (United States) Vol. 106:1; ISSN JSEED