Pretest analysis document for Test S-NH-1
This report documents the pretest analysis calculation completed with the RELAP5/MOD2/CY3601 code for Semiscale MOD-2C Test S-NH-1. The test will simulate the shear of a small diameter penetration of a cold leg, equivalent to 0.5% of the cold leg flow area. The high pressure injection system is assumed to be inoperative throughout the transient. The recovery procedure consists of latching open both steam generator ADV's while feeding with auxiliary feedwater, and accumulator operation. Recovery will be initiated upon a peak cladding temperature of 811 K (1000/sup 0/F). The test will be terminated when primary pressure has been reduced to the low pressure injection system setpoint of 1.38 MPa (200 psia). The calculated results indicate that the test objectives can be achieved and the proposed test scenario poses no threat to personnel or to plant integrity. 12 figs.
- Research Organization:
- EG and G Idaho, Inc., Idaho Falls (USA)
- DOE Contract Number:
- AC07-76ID01570
- OSTI ID:
- 6474749
- Report Number(s):
- EGG-RTH-7064; ON: TI86004143
- Country of Publication:
- United States
- Language:
- English
Similar Records
RELAP5 assessment using semiscale SBLOCA test S-NH-1. International Agreement Report
Pretest analysis document for Test S-FS-6
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
LOSS OF COOLANT
HEAT TRANSFER
HYDRAULICS
MOCKUP
PWR TYPE REACTORS
C CODES
COMPUTER CALCULATIONS
COMPUTER CODES
COMPUTERIZED SIMULATION
FEEDWATER
M CODES
R CODES
REACTOR MATERIALS
REACTOR VESSELS
RISK ASSESSMENT
SHEAR
SHEAR PROPERTIES
STEAM GENERATORS
TRANSIENTS
ACCIDENTS
BOILERS
CONTAINERS
ENERGY TRANSFER
FLUID MECHANICS
HYDROGEN COMPOUNDS
MATERIALS
MECHANICAL PROPERTIES
MECHANICS
OXYGEN COMPOUNDS
REACTOR ACCIDENTS
REACTORS
SIMULATION
STRUCTURAL MODELS
VAPOR GENERATORS
WATER
WATER COOLED REACTORS
WATER MODERATED REACTORS
220900* - Nuclear Reactor Technology- Reactor Safety
210200 - Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled