Investigation of fluid-bed combustion of municipal solid waste
Technical Report
·
OSTI ID:6469629
An experimental study was undertaken to burn processed municipal solid waste in a fluid-bed combustor containing water-cooled tubes in the bed. The 300-hour test was performed without incident and terminated on schedule. The combustor and ducting were clean on inspection after the test, and bed agglomeration did not occur. A corrosion tube placed in the free-board showed considerable metal wastage for carbon and low-alloy steels and some wastage for stainless steels. Low-temperature carbon steel water tubes in the bed showed negligible wastage. It was concluded that heat-exchanger tubes in the freeboard require protection from the high-velocity elutriated solids. Combustion efficiency was greater than 99%, and pollutants were measured as follows: SO/sub 2/ = 58 ppm, NOx = 178 ppm, CO = 242 ppm, hydrocarbons = 5.4 ppm. A system study was conducted for a cogeneration, 800-tons/day power plant to be located on the Stanford U. campus to supply all of the process steam requirement and as much of the electrical power as possible.
- Research Organization:
- Stanford Univ., CA (USA)
- OSTI ID:
- 6469629
- Report Number(s):
- PB-85-242121/XAB
- Country of Publication:
- United States
- Language:
- English
Similar Records
Investigation of fluid-bed combustion of municipal solid waste
Atmospheric fluidized bed combustion of municipal solid waste: test program results
Agglomeration of sorbent and ash carry-over for use in atmospheric fluidized-bed combustors
Technical Report
·
·
OSTI ID:5757656
Atmospheric fluidized bed combustion of municipal solid waste: test program results
Conference
·
Thu May 01 00:00:00 EDT 1980
·
OSTI ID:5160522
Agglomeration of sorbent and ash carry-over for use in atmospheric fluidized-bed combustors
Journal Article
·
Thu Mar 31 23:00:00 EST 1983
· Ind. Eng. Chem. Process Des. Dev.; (United States)
·
OSTI ID:5952090
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320603 -- Energy Conservation
Consumption
& Utilization-- Municipalities & Community Systems-- Public Utilities-- (1980-)
320604* -- Energy Conservation
Consumption
& Utilization-- Municipalities & Community Systems-- Municipal Waste Management-- (1980-)
42 ENGINEERING
421000 -- Engineering-- Combustion Systems
AIR POLLUTION CONTROL
COGENERATION
COMBUSTORS
COMPOSTING
CONTROL
DEUS
EFFICIENCY
ENERGY RECOVERY
ENERGY SYSTEMS
FLUIDIZED-BED COMBUSTORS
FUELS
INCINERATORS
MANAGEMENT
MUNICIPAL WASTES
POLLUTION CONTROL
POWER GENERATION
PROCESSING
RECOVERY
REFUSE DERIVED FUELS
STEAM GENERATION
WASTE MANAGEMENT
WASTE PROCESSING
WASTES
320603 -- Energy Conservation
Consumption
& Utilization-- Municipalities & Community Systems-- Public Utilities-- (1980-)
320604* -- Energy Conservation
Consumption
& Utilization-- Municipalities & Community Systems-- Municipal Waste Management-- (1980-)
42 ENGINEERING
421000 -- Engineering-- Combustion Systems
AIR POLLUTION CONTROL
COGENERATION
COMBUSTORS
COMPOSTING
CONTROL
DEUS
EFFICIENCY
ENERGY RECOVERY
ENERGY SYSTEMS
FLUIDIZED-BED COMBUSTORS
FUELS
INCINERATORS
MANAGEMENT
MUNICIPAL WASTES
POLLUTION CONTROL
POWER GENERATION
PROCESSING
RECOVERY
REFUSE DERIVED FUELS
STEAM GENERATION
WASTE MANAGEMENT
WASTE PROCESSING
WASTES