Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Shock sensitivity of LX 04 at elevated temperatures

Conference ·
OSTI ID:646422

Hazard scenarios can involve multiple stimuli, such as heating followed by fragment impact (shock). The shock response of LX-04 (85 weight % HMX and 15 weight % Viton binder) preheated to temperatures hear 170C is studied in a 10.2 cm bore diameter gas gun using embedded manganin pressure gauges. The pressure histories at various depths in the LX-04 targets and the run distances to detonation at several input shock pressures are measured and compared to those obtained in ambient temperature LX-04. The hot LX-04 is significantly more shock sensitive than ambient LX-04. Ignition and Growth reactive flow models are developed for ambient and hot LX-04 to allow predictions of impact scenarios that a can not be tested directly.

Research Organization:
Lawrence Livermore National Lab., CA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
646422
Report Number(s):
UCRL-JC--126563; CONF-970707--; ON: DE98050766
Country of Publication:
United States
Language:
English

Similar Records

Shock sensitivity of LX-04 at elevated temperatures
Journal Article · Wed Jul 01 00:00:00 EDT 1998 · AIP Conference Proceedings · OSTI ID:295484

Shock sensitivity of LX-04 at 150C
Conference · Tue Jun 01 00:00:00 EDT 1999 · OSTI ID:14188

Shock sensitivity of LX-04 at 150C
Conference · Tue Jun 01 00:00:00 EDT 1999 · OSTI ID:14325