Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Intergrated compartment-machine design for low-coal shuttle cars

Technical Report ·
OSTI ID:6444081
This report describes the development of a preliminary design for a novel, protected, cab-shuttle car for use in working seam heights down to 40 in. Because of the severe restrictions imposed by low-coal operation, Mine Safety and Health Administration (MSHA) regulations only require canopy protection on shuttle cars operating in seam heights of 42 in or greater. MSHA routinely grants variances for canopy use in seams 48 in high or less. The design was generated by giving the operator needs equal priority as related to machine performance parameters. Cab-shuttle car concepts that led to the recommended design are described, along with criteria and testing used to evaluate their potential effectiveness.
Research Organization:
Bureau of Mines, Pittsburgh, PA (USA)
OSTI ID:
6444081
Report Number(s):
IC-9200
Country of Publication:
United States
Language:
English