Severe accident sequences simulated at a VVER 440-213

Journal Article · · Transactions of the American Nuclear Society
OSTI ID:644279
 [1]
  1. Oak Ridge National Lab., TN (United States)

The MELCOR severe accident code version 1.8.4QK has been employed to calculate the timing of events and source terms released into the environment for several hypothetical severe accidents as Unit 1 of the Juragua VVER 440-213 plant, located near Cienfuegos, Cuba. Different severe accidents were simulated, and results from two of them are presented here. The two accidents presented are a station blackout and a large loss-of-coolant accident (LOCA) guillotine break in one cold leg concurrent with loss of all power. For both accidents, core safety injection systems, feedwater systems, and sprays are not available. Only the four passive accumulators are operational.

OSTI ID:
644279
Report Number(s):
CONF-980606--
Journal Information:
Transactions of the American Nuclear Society, Journal Name: Transactions of the American Nuclear Society Vol. 78; ISSN 0003-018X; ISSN TANSAO
Country of Publication:
United States
Language:
English

Similar Records

Accident sequences simulated at the Juragua nuclear power plant
Technical Report · Sat Aug 01 00:00:00 EDT 1998 · OSTI ID:665976

The VVER 440/230 confinement upgrade scoping study
Conference · Mon Dec 31 23:00:00 EST 1990 · Transactions of the American Nuclear Society; (United States) · OSTI ID:5977072

Evaluation of single failure effects during loss of coolant accidents for a VVER-440 reactor
Technical Report · Mon May 01 00:00:00 EDT 1995 · OSTI ID:71363