skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Chevron facility focused on commercial orifice-meter research

Journal Article · · Oil Gas J.; (United States)
OSTI ID:6441207

Research to determine the accuracy of commercial orifice meters for custody-transfer measurement has indicated that high-volume gas meters can be flow-proven while in such service. The research further yielded more accurate orifice-meter discharge coefficient equations (at Reynolds numbers greater than 4,000,000) than current equations of the International Standards Organization (ISO) and the American Petroleum Institute (API). These are partial findings of a major study conducted by Chevron Oil Field Research Co. at its Venice, La., calibration facility.

Research Organization:
Chevron Oil Field Research Co., La Habra, CA
OSTI ID:
6441207
Journal Information:
Oil Gas J.; (United States), Vol. 85:30
Country of Publication:
United States
Language:
English

Similar Records

Field calibration of orifice meters for natural gas flow
Journal Article · Wed Mar 01 00:00:00 EST 1989 · Journal of Energy Resources Technology; (USA) · OSTI ID:6441207

Research yields precise uncertainty equations
Journal Article · Mon Aug 03 00:00:00 EDT 1987 · Oil Gas J.; (United States) · OSTI ID:6441207

Velocity profile survey in a 16-in. custody-transfer orifice meter for natural gas