Sloshing and fluid-structure interaction in a 400-MWe pool-type advanced fast reactor

Conference ·
OSTI ID:6439935
This paper describes the seismic analysis of a 400-MWe advanced fast reactor under 0.3 g SSE ground excitation. Two types of analyses are performed - the sloshing analysis and the fluid-structure interaction analysis. In the sloshing analysis, the sloshing frequency and wave patterns are calculated. The maximum wave height and the sloshing forces exerted on the submerged components and the primary tank are evaluated. In the fluid-structure interaction analysis, the maximum horizontal acceleration for the reactor core and the relative displacement between the reactor core and UIS are examined. The fluid-coupling phenomena between various components are investigated. Seismic stresses at critical areas are examined. The results obtained from this study are very useful to the design of the advanced reactors. Meanwhile, the computer code FLUSTR-ANL has proved to be a useful analytical tool for assessing the complicated seismic fluid-structure interactions and sloshing in the fast reactor systems. 10 refs., 25 figs.
Research Organization:
Argonne National Lab., IL (USA)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
6439935
Report Number(s):
CONF-870636-13; ON: DE87011441
Country of Publication:
United States
Language:
English