Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Steam generator chemical cleaning demonstration test No. 1 in a pot boiler. [PWR]

Technical Report ·
DOI:https://doi.org/10.2172/6425603· OSTI ID:6425603
The effectiveness of the Electric Power Research Institute (EPRI Mark I) chemical cleaning solvent process was tested utilizing a 12 tube pot boiler that had previously been fouled and dented under 30 days of high chloride fault chemistry operation. Specifically, the intent of this chemical cleaning test was to: (1) dissolve sludge from the tubesheet, (2) remove non-protective magnetite from dented tube/support crevice regions, and (3) quantify the extent of corrosion of steam generator material during the test. Two laboratory cleaning demonstrations of 191 and 142 hours were performed.
Research Organization:
Combustion Engineering, Inc., Windsor, CT (USA). Nuclear Power Dept.
OSTI ID:
6425603
Report Number(s):
EPRI-NP-1789
Country of Publication:
United States
Language: