Experimental analysis of Kevlar modification for TRUPACT-I puncture panels. [Drop tests; radiant heat tests]
The Kevlar Test Services was initiated to determine the maximum failure force and the energy-absorbing capability of puncture panels consisting of 16, 20, and 24 layers of 3000-denier 4 x 4 basket weave Kevlar-29, bonded to a 3.41 mm 304 annealed stainless steel puncture plate. Results of these tests were compared to the TRUPACT-1 Unit-0 drop test results to determine if the existing puncture panel configuration of TRUPACT-1 could be reduced. The data indicate for 24 layers of Kevlar, the panels failed at loads greater than those recorded in the TRUPACT-1, Unit 0 tests. Energy absorbed by the 24-layer Kevlar panels was 53% greater than that measured in the TRUPACT-1, Unit 0 test. Thermal performance of 20-layer Kevlar panels was measured in a conservative test environment and exceeded the design specifications.
- Research Organization:
- Sandia National Labs., Albuquerque, NM (USA)
- DOE Contract Number:
- AC04-76DP00789
- OSTI ID:
- 6418244
- Report Number(s):
- SAND-86-1690; ON: DE87010525
- Country of Publication:
- United States
- Language:
- English
Similar Records
Puncture protection for the TRUPACT system
Developing TRUPACT system impact resistance
Related Subjects
420204* -- Engineering-- Shipping Containers
ABSORPTION
ARAMIDS
CHEMICAL REACTIONS
COLLOIDS
COMBUSTION
DISPERSIONS
ENERGY ABSORPTION
ENERGY TRANSFER
FOAMS
HEAT TRANSFER
IMPACT TESTS
MATERIALS
MATERIALS TESTING
MECHANICAL TESTS
MODIFICATIONS
OXIDATION
PACKAGING
PETROCHEMICALS
PETROLEUM PRODUCTS
PLASTICS
RADIANT HEAT TRANSFER
SYNTHETIC MATERIALS
TEMPERATURE DISTRIBUTION
TESTING
THERMOCHEMICAL PROCESSES