Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Experimental analysis of Kevlar modification for TRUPACT-I puncture panels. [Drop tests; radiant heat tests]

Technical Report ·
OSTI ID:6418244

The Kevlar Test Services was initiated to determine the maximum failure force and the energy-absorbing capability of puncture panels consisting of 16, 20, and 24 layers of 3000-denier 4 x 4 basket weave Kevlar-29, bonded to a 3.41 mm 304 annealed stainless steel puncture plate. Results of these tests were compared to the TRUPACT-1 Unit-0 drop test results to determine if the existing puncture panel configuration of TRUPACT-1 could be reduced. The data indicate for 24 layers of Kevlar, the panels failed at loads greater than those recorded in the TRUPACT-1, Unit 0 tests. Energy absorbed by the 24-layer Kevlar panels was 53% greater than that measured in the TRUPACT-1, Unit 0 test. Thermal performance of 20-layer Kevlar panels was measured in a conservative test environment and exceeded the design specifications.

Research Organization:
Sandia National Labs., Albuquerque, NM (USA)
DOE Contract Number:
AC04-76DP00789
OSTI ID:
6418244
Report Number(s):
SAND-86-1690; ON: DE87010525
Country of Publication:
United States
Language:
English