Diagnostics for slapper detonator systems
This report discusses diagnostics which have been used to evaluate CDU characteristics and performance, slapper characteristics and performance and the response of a HE detonator output pellet to a slapper stimulus. Many of the diagnostics discussed are appropriate for development and production testing. These include CVR current measurements, voltage probe measurements, time-of-flight measurements, threshold measurements, function time measurements, use of steel witness plates and determination of design margin. Some of the more-sophisticated, expensive diagnostics discussed have yielded very useful information, but are not required for development and production testing. 8 refs., 9 figs., 1 tab.