Title: End-Use Load and Conservation Assessment Program : Co-Instrumentation Test of Two Microcomputer-Based Energy Monitoring Systems.

Technical Report ·
OSTI ID:6413700

The decreasing cost of microcomputers along with improvements in power metering circuitry have changed the way in which electrical energy use is monitored. Although utilities still rely on kilowatt-hour (kWh) meters for billing purposes, a microcomputer-based monitoring system is used when greater temporal and end-use resolution is desired. Because these types of monitoring systems will be used increasingly in large-scale conservation and end-use studies, it is important that their performance be analyzed to determine their accuracy. A co-instrumentation test was devised in which two such microcomputer-based monitoring systems made simultaneous measurements of electrical end-uses in two commercial buildings. The analysis of the co-instrumentation data aids in the evaluation of microcomputer-based monitoring systems used for end-use measurements. Separate and independent data loggers were used to measure the same loads simultaneously. In addition to these two systems, a utility billing meter measured the total energy use in each building during the co-instrumentation test. The utility's meters provided a relatively accurate standard by which the performance of both loggers could be judged. The comparison between the SCL and PNL microcomputer-based loggers has shown that power measurement techniques directly affect system performance. The co-instrumentation test has shown that there are certain standards that a monitoring system must meet if it is to perform well. First, it is essential to calibrate a microcomputer-based logger against a known standard load before the system is installed. Second, a microcomputer-based system must have some way of accounting for power factors. Recent advances in power metering circuitry have made it relatively easy to apply these power factors automatically in real time.

Research Organization:
Pacific Northwest Labs., Richland, WA (USA); Seattle City Light, WA (USA)
Sponsoring Organization:
United States. Bonneville Power Administration.
DOE Contract Number:
AC79-83BP13795
OSTI ID:
6413700
Report Number(s):
DOE/BP-13795-2; ON: DE85017297
Resource Relation:
Related Information: Co-instrumentation test : ELCAP
Country of Publication:
United States
Language:
English